Ada door handle height requirement.
Commercial ada door handle height. In the previous edition of the ada standard section 4 13 9 included this statement. The ada compliance guidelines state that if the shape of the door hardware inhibits the user from operating the door handle it will not pass inspection. By the year 2030 71 5 million baby boomers will be over the age of 65 and demanding products services and environments that address their age related physical. Door handles pulls latches locks and other operating devices shall be installed 34 inches 864 mm minimum and 48 inches 1219 mm maximum above the finished floor.
Effort to operate doors 8 5 pounds at exterior doors and 5 pounds at interior doors door hardware height 30 44 above floor. Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground. Specifically door handles pulls latches locks and other operating devices on accessible doors must be. Door hardware operable with a single effort without requiring ability to grasp hardware.
Inaccessible door hardware can also prevent access to the business. For example the handle shown below requires the user to tightly grasp the handle to open the door. Pre existing locks most likely not applicable to new builds gates protecting pools spas and hot tubs are allowed to be a bit higher up to 54. Handles pulls panic bars.
Hardware required for accessible door passage shall be mounted no higher than 48 in 1220 mm above finished floor. Size min 3 0 wide 32 clear when 90 open and 6 8 in height. A few exceptions are included in the bill. This guide explains scoping and technical requirements for accessible entrances doors and gates in the ada standards.
With an age growing population fast approaching an all time high more and more building codes are specifying ada american disabilities act compliant products and standards. If a door has a closer then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees the door will take at least 3 seconds to move to a point 3 in 75 mm from the latch. Ada american disabilities act compliant door hardware. Minimum number at least 60 of public entrances must be accessible in new construction in addition to entrances directly serving tenancies parking facilities pedestrian tunnels and elevated walkways.
Hardware required for accessible door passage shall be mounted no higher than 48 in 1220 mm above finished floor. The height of the door handle must be between a minimum of 34 and a maximum of 48. Operable parts shall be operable with one hand and shall not require tight grasping pinching or twisting of the wrist.