Class 1 Division 1 Electrical Wiring
501 10 b class i division 2.
Class 1 division 1 electrical wiring. 1 how to connect a flexible metal conduit to a elbow in a class 1 division 2 area as per nfpa 70. There are four general differences in wiring method requirements for div. The rules in chapter 5 often modify or amend the general requirements in chapters 1 through 7. National electrical code nfpa 70 chapter 5 article 500.
Traditionally division classifications were used in north america while zone classifications were used elsewhere. Where combustible dust is present in the air under normal operating conditions in such a quantity as to produce explosive or ignitable mixtures. Question asked by vegi on feb 21 2017 latest reply on mar 2 2017 by barry emfinger. In electrical and safety engineering hazardous locations hazloc pronounced haz lōk are places where fire or explosion hazards may exist.
Recommended reading for this topic. If a wiring method is allowed for div. 1 it s also allowed for div. In the case of hazardous locations these modifications are usually more restrictive.
1910 307 a scope 1910 307 a 1 applicability this section covers the requirements for electric equipment and wiring in locations that are classified depending on the properties of the flammable vapors liquids or gases or combustible dusts or fibers that may be present therein and the likelihood that a flammable or combustible concentration or quantity is present. This column reviews a few important conduit seal requirements for wiring in class i division 1 hazardous locations. Electrical wiring for class 1 division 2 wiring as per nfpa 70. Like show 0 likes 0.
505 permitting optional use of zones 0 1 and 2 within class i areas and zones 20 21 and 22 within class ii and iii areas. Protection techniques for hazardous areas north america. Sources of such hazards include gases vapors dust fibers and flyings which are combustible or flammable. One of the following three situations must exist in order for an area to be considered a class ii division 1 location.
In class i division 2 locations all wiring methods permitted in 501 10 a and the following wiring methods shall be permitted. Use of the zone method allows designers to specify offshore equipment. A class 1 circuit is the portion of the wiring system between the load side of the overcurrent protection device ocpd or the power limited supply and the connected load. Class ii division 1.
Electrical equipment installed in such locations could provide an ignition source due to electrical arcing or high temperature. In recent years the nec added art. Zone 2 group iia. 1 rigid metal conduit rmc and intermediate metal conduit imc with listed threadless fittings.
Class i division 2 group d. Also class 1 remote control circuits are limited up to 600 volts with no other. Do i have to use a sealant on the threading of the elbow. For example class 1 power limited circuits are supplied by a power supply with an output that does not exceed 30 volts and 1 000 volt amps.
2 enclosed gasketed busways and enclosed gasketed wireways.