Class 1 Division 1 Electrical Equipment
Electrical equipment installed in such locations could provide an ignition source due to electrical arcing or high temperature.
Class 1 division 1 electrical equipment. Class i locations consist of areas where gases vapors or liquids may exist that have the potential to become flammable or ignitable. Note to paragraph g 4 of this section. Sources of such hazards include gases vapors dust fibers and flyings which are combustible or flammable. Division probability of hazardous material.
Low ambient conditions require special consideration. 1 it s also allowed for div. The most widely used and recognizable equipment in class i division 1 locations is explosionproof equipment which is defined in art. Or breakdown or faulty operation of equipment which causes them to become a source of ignition.
In electrical and safety engineering hazardous locations hazloc pronounced haz lōk are places where fire or explosion hazards may exist. Under normal operating conditions 2. For definitions of these locations see 1926 449. If equipment has been approved for use in a division 1 hazardous location it can be used in a division 2 hazardous location providing it is in the same class and group.
Class i division 1 class i division 2 class ii division 1 class ii division 2 class iii division 1 class iii division 2. 1 areas must be listed for class i div. Equipment suitable for class ii division 1 is permissible as well as equipment with the noted types of protection in b and. Can i use a piece of equipment approved for use in a division 1 hazardous location in a division 2 hazardous location.
A class i division 1 or division 2 location may be reclassified as a class i zone 0 zone 1 or zone 2 location only if all of the space that is classified because of a single flammable gas or vapor source is reclassified. There are two different divisions that exist in class i division 1 and division 2 along with three zones. If a wiring method is allowed for div. The substance referred to by class has a high probability of producing an explosive or ignitable mixture due to it being present continuously intermittently or periodically or from the equipment itself under normal operating conditions.
Class 1 division 1 defines a specific hazardous location in which ignitible flammable gases or vapors exist. Because of repair maintenance or leakage. There are four general differences in wiring method requirements for div. Zone 0 1 2.
Locations that would be considered to be class i include petroleum refineries gasoline storage areas dry cleaning plants spray finishing. 1 fittings and flexible cords used in class i div. Rule 18 202 rigid metal conduit hazardous location cables explosion proof or flame proof d boxes and fittings with threaded connection to conduit and cable glands shall be used for wiring in zone 21.